अमूर्त

Performance of Conventional X Chart for Auto- Correlated Data Using Subgroup Size of Ten

D. R. Prajapati

Control charts have been used to monitor and control the production process and generate some sort of signal when there are indications to the effect that the process has gone out of control. Conventional (Shewhart) X charts were originally developed by Walter F. Shewhart (1931). The limits of the chart are known as upper control limit (UCL) and lower control limit (LCL). He suggested two control limits i.e. UCL = X + 3σ/√n and LCL = X - 3σ/√n, where X is the target mean, σ is population standard deviation and n is the sample size. In implementing the X chart, it is assumed that the process outputs must be IID but usually there is some correlation among the data. When this correlation builds up automatically in the entire process, this phenomenon is called autocorrelation. It is found that the performance of conventional X chart deteriorates on increasing the level of correlation.

अस्वीकृति: इस सारांश का अनुवाद कृत्रिम बुद्धिमत्ता उपकरणों का उपयोग करके किया गया है और इसे अभी तक समीक्षा या सत्यापित नहीं किया गया है।

में अनुक्रमित

Academic Keys
ResearchBible
CiteFactor
Cosmos IF
RefSeek
Hamdard University
World Catalogue of Scientific Journals
Scholarsteer
International Innovative Journal Impact Factor (IIJIF)
International Institute of Organised Research (I2OR)
Cosmos

और देखें